inthesingularity.ai
Wire · Data centers · Malaysia

W.126Malaysia plans a law making data centres report power use and GPU imports

Malaysia’s trade minister said on November 12 that data centres will be required by law to disclose their electricity use and the number of GPU chips they import. No bill or date has been given. He said 55 of 117 approved projects are operating. The energy minister told parliament in October that data centres drew 1,374 MW in August against 2,346 MW contracted, 58.5%. The trade minister said the monthly charge on unused booked capacity has been raised from RM8.50 to RM89.64 per kW; no effective date was given.

Approved data-centre projects operating
55 of 117
47%; RM385.7B approved since 2021
Contracted power in use, August 2026
58.5%
1,374 of 2,346 MW; 972 MW unused
Data-centre load on Tenaga’s grid, June 2026
1,256 MW
2.1 times June 2025’s 603 MW
Charge on unused booked capacity, per kW a month
RM89.64
from RM8.50; 10.5 times

What was said

The minister announced an intention, not a bill. Johari Abdul Ghani, the investment, trade and industry minister, said the requirement to disclose data-centre operations will be embedded in law, Bernama reported on November 12. The information is to include electricity use and the number of imported GPU chips. He said the government needs to know the operator, the hyperscaler and the location of each data centre. Bernama’s report names no Act, no tabling date and no ministry that will draft it. The Epoch Times wrote on November 13 that the rules have not been enacted.

Fewer than half the approved projects are running. Johari said 55 of 117 approved projects have begun operations, 47%. He gave the full breakdown to parliament on October 28: 19 under construction, 16 not yet started, and 27 at various stages that are expected to use off-grid electricity. The investment agency MIDA puts approvals at RM385.7B from 2021 to the first half of 2026, which the Epoch Times converted to about $94.7B. Another 24 applications are on hold pending water and power checks.

Chip imports are the gap the plan addresses. Since July 2025 Malaysia has required a permit to export, re-export, tranship or transit high-performance US AI chips. Importing them needs no permit, the ministry said on November 13. Johari said some parties had rented space in local data centres, imported GPU chips and later re-exported them, and that the Digital Ministry is reviewing whether existing laws allow action.

55 of the 117 approved projects are operating; 27 are expected to run off the grid

Malaysia’s 117 approved data-centre projects by status, as the trade minister gave it to parliament on October 28, 2026. Number of projects. Dashed: projects at various stages that are expected to use off-grid electricity.

0204060OperatingOperating: 55 of 117 projects, 47%55Under constructionUnder construction: 19 of 117 projects, 16%19Not yet startedNot yet started: 16 of 117 projects, 14%16At various stages, expected to use off-grid powerAt various stages, expected to use off-grid power: 27 of 117 projects, 23%27
0204060OperatingOperating: 55 of 117 projects, 47%55BuildingUnder construction: 19 of 117 projects, 16%19Not startedNot yet started: 16 of 117 projects, 14%16Off-grid, variousAt various stages, expected to use off-grid power: 27 of 117 projects, 23%27

What the power figures show

Data centres used 58.5% of the power they had contracted, the energy minister said. Fadillah Yusof, the deputy prime minister and energy minister, told parliament on October 28 that data centres’ actual consumption in August was 1,374 MW against contracted demand of 2,346 MW. That leaves 972 MW contracted and not drawn.

The load has roughly doubled in a year. Tenaga Nasional, the grid utility, reports the load data centres draw at each quarter end. It was 1,256 MW in June 2026, 2.08 times the 603 MW of June 2025. Tenaga’s contracts are take-or-pay for the first five years, RHB said in July after meeting its management.

The measures of capacity differ by a factor of about seventeen. Tenaga counted 61 secured projects with 8.35 GW of maximum demand at June 30, of which 42 with 5.65 GW were completed. June’s load was 22% of the completed projects’ maximum demand. The energy ministry says projects had been approved for 12.3 GW of supply capacity by August. Johari said demand would reach 23,000 to 23,500 MW if all 117 approved projects were completed, 17 times August’s draw. The projection the energy minister gave for 2030 is 8,391 MW. The counts may be on different bases: Tenaga’s 42 are projects completed and in its system, while the trade ministry’s 55 are counted from investment approvals; neither source reconciles them.

Data-centre load on Tenaga’s grid reached 1,256 MW in June, 2.1 times a year earlier

Electricity load drawn by data centres on Tenaga Nasional’s system at each quarter end, megawatts, from its analyst briefings. Pink: June 2026, the latest reported.

05001,0001,500Dec 2024: 405 MW of data-centre load405Dec 2024Mar 2025: 485 MW of data-centre load485Mar 2025Jun 2025: 603 MW of data-centre load603Jun 2025Sep 2025: 710 MW of data-centre load710Sep 2025Dec 2025: 850 MW of data-centre load850Dec 2025Mar 2026: 1,054 MW of data-centre load1,054Mar 2026Jun 2026: 1,256 MW of data-centre load1,256Jun 2026
05001,0001,500Dec 2024: 405 MW of data-centre load405Dec’24Mar 2025: 485 MW of data-centre load485Mar’25Jun 2025: 603 MW of data-centre load603Jun’25Sep 2025: 710 MW of data-centre load710Sep’25Dec 2025: 850 MW of data-centre load850Dec’25Mar 2026: 1,054 MW of data-centre load1,054Mar’26Jun 2026: 1,256 MW of data-centre load1,256Jun’26

August’s draw was 1.37 GW; approved projects would need 23 GW or more

Six official measures of data-centre power in Malaysia, megawatts shown as gigawatts. Pink: power drawn in August 2026. Strong grey: demand contracted in August 2026, both from the energy minister. Grey: the maximum demand of Tenaga’s completed and of all its secured projects at June 30, 2026. Faint grey: supply capacity approved by August 2026 (energy ministry) and the trade minister’s figure for demand if all 117 approved projects are completed, with the outline marking the top of his range. The measures have different sources, dates and definitions and are not parts of one total.

06 GW12 GW18 GW24 GWDrawn by data centresAugust 2026, energy ministryDrawn by data centres, August 2026, energy ministry: 1,374 MW1.37 GWContracted demandAugust 2026, energy ministryContracted demand, August 2026, energy ministry: 2,346 MW2.35 GWCompleted projects, maximum demandJune 2026, TenagaCompleted projects, maximum demand, June 2026, Tenaga: 5,650 MW5.65 GWAll secured projects, maximum demandJune 2026, TenagaAll secured projects, maximum demand, June 2026, Tenaga: 8,350 MW8.35 GWSupply capacity approvedAugust 2026, energy ministrySupply capacity approved, August 2026, energy ministry: 12,300 MW12.30 GWIf all 117 projects are completedtrade ministerIf all 117 projects are completed, trade minister: 23,000 MWUp to 23,500 MW23–23.5 GW
012 GW24 GWDrawnDrawn by data centres, August 2026, energy ministry: 1,374 MW1.37 GWContractedContracted demand, August 2026, energy ministry: 2,346 MW2.35 GWCompletedCompleted projects, maximum demand, June 2026, Tenaga: 5,650 MW5.65 GWSecuredAll secured projects, maximum demand, June 2026, Tenaga: 8,350 MW8.35 GWApprovedSupply capacity approved, August 2026, energy ministry: 12,300 MW12.30 GWAll 117If all 117 projects are completed, trade minister: 23,000 MWUp to 23,500 MW23–23.5 GW
Tenaga’s secured projects, June 30, 2026
StageProjectsMaximum demand, GW
Completed425.65
Under construction162.21
Supply agreement signed, not started30.49
Total618.35

Tenaga Nasional, 2QFY2026 analyst briefing. Johor accounts for 29 of the projects and 5.6 GW.

What unused capacity will cost

The charge for unused capacity is an existing rule with a higher rate. Johari’s example was a centre that books 100 MW, uses 50 MW and is still billed for the rest. Under trade ministry rules that The Edge reported in December 2025, a data centre must use 85% of its declared maximum demand in its first four years and 75% in years five and six, and pays a monthly charge of RM8.50 per kW on the shortfall, the rate the minister calls the Connected Load Charge. On November 10 Johari said the charge had been raised from RM8.50 to RM89.64 per kW, The Star reported. The effective date was not stated, and Tenaga’s website still showed the old rate when w.media published on November 12.

Each unused megawatt would cost RM89,640 a month. At the old rate it cost RM8,500. As an illustration, if the charge applies to the shortfall below the 85% floor, the centre in Johari’s example falls 35 MW short and would pay about RM3.1M a month, against about RM0.3M before. How the charge is computed in a given contract is not public.

The charge on unused booked capacity rises 10.5 times

Malaysia’s Connected Load Charge in ringgit per kilowatt per month: the previous rate and the rate the trade minister stated on November 10, 2026. The effective date of the new rate has not been stated.

RM0RM25RM50RM75RM100Previous rateper kW per monthPrevious Connected Load Charge: RM8.50 per kW per monthRM8.50Stated November 10per kW per monthConnected Load Charge stated November 10, 2026: RM89.64 per kW per monthRM89.64
RM0RM25RM50RM75RM100PreviousPrevious Connected Load Charge: RM8.50 per kW per monthRM8.50New rateConnected Load Charge stated November 10, 2026: RM89.64 per kW per monthRM89.64

What is not known

The plan has no text. Nothing published says whether operators would report chip models, serial numbers or only counts, how often, or to whom. Tom’s Hardware’s headline said real-world variance in chip power draw and a lack of physical audits could undermine the plan.

No re-export by Speedmatrix has been established. The ministry said on November 13 that it never cleared Megaspeed or its Malaysian affiliate Speedmatrix, and that it is working with customs to determine whether chips imported for Speedmatrix were re-exported. Megaspeed bought nearly $2B of Nvidia chips through a Malaysian subsidiary, Asia Times wrote in June, citing earlier US press reports. Megaspeed said on November 12 that it cooperated with US inspections and hired an American law firm to inventory its GPUs, the Epoch Times reported.

What this changes on inthesingularity.ai

  • W.094 set a credible share against an announced North American pipeline. Lead: Malaysia publishes the same ladder officially, from 1.37 GW drawn to 23 GW or more approved. A tracker of Tenaga’s quarterly load against its secured maximum demand would show how fast the gap closes.
  • Which Texas data centers are at risk? Lead: Malaysia’s trade minister says the charge on reserved and unused grid capacity has been raised to RM89.64 per kW a month, with no effective date stated. A comparison with what US utilities charge large loads for unused reservations would test whether such charges thin a queue.
  • W.054 and W.106 followed restricted Nvidia chips through Southeast Asia. Lead: if the law is tabled, the count of imported GPUs per site would be the first official data on where the chips are.

Sources and method

ItemFigureSource
The planDisclosure of data-centre operations, including electricity use and the number of imported GPU chips, to be embedded in law; 55 of 117 approved projects operating; a centre that books 100 MW and uses 50 MW is still billed for the unused 50 MW; the Digital Ministry is reviewing existing laws on re-exports of US-restricted GPU chips. No bill, Act or date givenBernama, Nov 12
Approved projects117 approved data centres, RM385.7B: 55 operating; 19 under construction; 16 not yet started; 27 at various stages, expected to use off-grid power. Demand of 23,000–23,500 MW if all are completed; 24 new applications on hold pending water and power checksFree Malaysia Today, Oct 28
Approved projectsRM385.7B of data-centre-related investment approved from 2021 to the first half of 2026MIDA, Sep 14
Approved projectsFirst half of 2026: RM95.8B of data-centre and cloud projects in RM218.5B of approved investmentThe Edge Malaysia, Sep 14
Approved projectsData centres were 0.4% of approved investment in 2021 and 43.9% in the first half of 2026; Connected Load Charge raised from RM8.50 to RM89.64 per kWThe Star, Nov 11
Approved projectsRM385.7B given as about $94.7B; the disclosure rules have not been enacted; Megaspeed said it cooperated with US inspections and hired a US law firm to inventory its GPUsThe Epoch Times, Nov 13
PowerAugust 2026: data centres drew 1,374 MW against contracted demand of 2,346 MW, 58.5%The Star, Oct 28
PowerData-centre projects approved for 12.3 GW of supply capacity as of August 2026; demand projected at 8,391 MW by 2030The Star, Oct 21
PowerData-centre load: 850 MW (Dec 2025), 1,054 MW (Mar 2026), 1,256 MW (Jun 2026). Secured projects at June 30, 2026: 42 completed with 5.65 GW of maximum demand, 16 under construction with 2.21 GW, 3 signed and not started with 0.49 GW; 61 in all, 8.35 GW. Johor: 29 projects, 5.6 GW of 8.3 GWTenaga Nasional, 2QFY2026 analyst briefing, Aug 28
PowerData-centre load: 485 MW (Mar 2025), 603 MW (Jun 2025), 710 MW (Sep 2025)Tenaga Nasional, 1QFY2026 analyst briefing, May 26
PowerData-centre load: 405 MW (Dec 2024)Tenaga Nasional, 4QFY2025 analyst briefing, Feb 27
PowerContracts are take-or-pay for the first five years, per RHB after meeting Tenaga’s managementThe Star, Jul 13
The chargeData centres must use 85% of declared maximum demand in years one to four and 75% in years five and six; the shortfall is charged RM8.50 per kW a monthThe Edge Malaysia, Dec 29, 2025
The chargeThe effective date of the new rate was not stated; Tenaga’s website still showed the old rate when the article was publishedw.media, Nov 12
ChipsMITI never cleared Megaspeed or Speedmatrix; it is working with customs to determine whether AI chips imported for Speedmatrix were re-exported; importing servers and AI chips needs no permit; a permit has been mandatory since July 2025 to export, re-export, tranship or transit high-performance US AI chipsThe Edge Malaysia, Nov 13
ChipsThe July 14, 2025 permit requirement, under the Strategic Trade Act 2010The Star, Jul 14, 2025
ChipsMegaspeed bought nearly $2B of Nvidia chips through a Malaysian subsidiary, citing earlier US press reportsAsia Times, Jun 3

What we read. The minister’s remarks are as Bernama reported them. We could not open the Tom’s Hardware article and use only its headline. Tenaga’s figures are from its analyst-briefing slides. Projects. 55 + 19 + 16 + 27 = 117; 55 ÷ 117 = 47.0%. Power. 1,374 ÷ 2,346 = 58.57%, which the minister gave as 58.5%; 2,346 − 1,374 = 972 MW. Load: 1,256 ÷ 603 = 2.08; 1,256 MW ÷ 5,650 MW of completed maximum demand = 22.2%; ÷ 8,350 MW secured = 15.0%. Tenaga publishes no such percentage. 23,000 ÷ 1,374 = 16.7. Tenaga’s stages: 5.65 + 2.21 + 0.49 = 8.35 GW. The charge. 89.64 ÷ 8.50 = 10.55; RM89.64 × 1,000 kW = RM89,640 per MW a month; RM8.50 × 1,000 = RM8,500. Illustration: 100 MW × 85% = 85 MW; 85 − 50 = 35 MW; × RM89,640 = RM3.14M a month; × RM8,500 = RM0.30M. The illustration assumes the charge applies each month to the shortfall below the 85% floor; the minister’s own wording was that the unused 50 MW is billed. Caveats: the energy ministry’s 58.5% and our 22% use different denominators and dates, the first the demand contracted in August and the second the maximum demand of Tenaga’s completed projects in June, and should not be mixed. The RHB account of five-year take-or-pay terms and the trade ministry’s 85% rule describe the terms differently. The dollar figure is the Epoch Times’ conversion, which we did not recompute. Not used: a $47B figure in one headline, which we could not trace to an official source; trade data on Taiwan’s computer exports to Malaysia, which do not isolate GPUs.

Wire reports are written within hours of the news, on a six-hour schedule. Each lists its sources and shows the arithmetic behind its figures. Not investment advice.